• 2kw 24VDC40A Power Inverter Charger AGM / GEL / LFP / Flooded Battery Type
  • 2kw 24VDC40A Power Inverter Charger AGM / GEL / LFP / Flooded Battery Type
  • 2kw 24VDC40A Power Inverter Charger AGM / GEL / LFP / Flooded Battery Type
  • 2kw 24VDC40A Power Inverter Charger AGM / GEL / LFP / Flooded Battery Type
2kw 24VDC40A Power Inverter Charger AGM / GEL / LFP / Flooded Battery Type

2kw 24VDC40A Power Inverter Charger AGM / GEL / LFP / Flooded Battery Type

Product Details:

Place of Origin: China
Brand Name: TBB
Certification: CE,ISO9000
Model Number: cs3060m

Payment & Shipping Terms:

Minimum Order Quantity: 1piece
Price: Negotiable
Packaging Details: Carton box, Honeycomb plate, Plywood crate
Delivery Time: 3-7 working days, depending
Payment Terms: T/T
Get Best Price Contact Now

Detail Information

AC Output: 230VAC/50HZ Model: Cs2040m
Output Type: Single Battery Type: AGM / GEL / LFP / Flooded
Application: Power Backup System Dc Input: 48VDC
Capacity: 2kw Current: 40A
High Light:

inverter battery charger

,

pure sine wave inverter charger

Product Description

2kw 24VDC40A Power Inverter Charger AGM / GEL / LFP / Flooded Battery Type

dc to ac power inverter charge combi 2kw 24VDC40A 230VAC/50HZ  cs2040m

 

Energier essential bi-directional inverter was especially designed for Power Shedding application, of which providing true sine-wave inverter, multistage battery charging and a transfer switch in together. It can be connected to either grid or generator to compose power system for the most demanding mobile, off grid and power backup application.

 

With AC input available from the grid or generator, power is pass through Energier essential bi-directional inverter to operate connected AC load and being covered to DC to charger the battery at the meantime. If AC input power failed or fall out of specification and is no longer qualified as good AC, a quick transfer take place and Energier essential bi-directional inverter start converting DC power from battery into AC power to supply connected AC load.

 

 
Features,
 
-TBB premium II multi stage charging algorithm with built in
-Bi directional inverter with pure sine wave output
-Optional CM was available for automatic generator start
-Optional SNMP card for remote internet access
-High performance designed for all kinds of home appliances
-Designed to work with weak grid

 

-Designed for tropical region with working temperature up to 60℃
-Compatible with majority of cheap generators in the market
-Can be applied for power backup and solar hybrid system
-Equalization charging program was available
 
Connecting the cable
 
Please make sure Energier essential bi-directional inverter is turned off before connection. Otherwise, high voltage could be present.
 
Please double check battery voltage match the model you are going to installed, the wrong battery could destroy equipment and is out of warranty.
 
Please double confirm the polarity of DC input. Reverse polarity could cause permanent damage on equipment and it is out of warranty.
2kw 24VDC40A Power Inverter Charger AGM / GEL / LFP / Flooded Battery Type 0
 
Specification

Model No. 12Vdc CS0625L CS1040L CS2080L    
  24Vdc CS0615M CS1020M CS2040M CS3060M CS4080M
  48Vdc       CS3030S CS4040S
INVERTER
Nominal Voltage 12Vdc, 24Vdc, 48Vdc
power 30mins @25℃ (W) 600 1000 2000 3000 4000
Cont.power@25℃ (W) 600 1000 1800 2500 3600
Cont.power@40℃ (W) 600 1000 1500 2000 3000
Cos φ 0.9-1
Surge 300%
Output voltage【1】 230VAC or 110VAC ± 2% 230VAC ± 2%
Output frequency 50Hz or 60Hz ± 0.1%
Efficiency (MAX.) 12Vdc 88%
  24Vdc 88%
  48Vdc 92%

Bypass
range

UPS mode 184VAC-264VAC/92VAC-132VAC 184VAC-264VAC
  GEN mode 160VAC-280VAC/80VAC-140VAC 160VAC-280VAC
Crest factor 3:1
THD <3%
Zero load power 17 22 27 36 62
Zero load power (power save mode) 4 5 7 9 15
Output circuit breaker 5A 10A 15A 30A 30A
Overheat protection auto disconnect
Overload protection auto disconnect
shortcut protection auto disconnect
Charger
Nominal Output Voltage 12Vdc, 24Vdc, 48Vdc
Max Output current (A) - adjustable 25/15 40/20 80/40 60/30 80/40
AC Input range UPS mode 184VAC - 264VAC/92VAC-132VAC 184VAC - 264VAC
  GEN mode 160VAC - 280VAC/80VAC-140VAC 160VAC - 280VAC
Battery types AGM / GEL / LFP / Flooded
Absorption time variable
Temperature compensation -4mV/℃/cell
Charger circuit breaker 5A 10A 15A 30A 30A
Other Data
Transfer time UPS mode 15ms
  GEN mode 2s
Transfer switch 40A
Battery connector M8 x 2
AC connector Terminal block (M3 screw)
Mechanical Data
Enclosure Steel with powder paint
Dimension (mm) 444x186x135 512x216x176
Net Weight (kgs) 9.5 14 16 18.5 22.5
Cooling Forced fan
Protection IP20
Standard
Safety EN60950-1
EMC EN55022,EN55024
【1】Output voltage: 220VAC/60Hz for Philippines

 