Self - Cooling 24v / 48v Dc Ups Power Supply Idu Device For Industrial
Product Details:
Place of Origin: | China |
Brand Name: | TBB |
Certification: | CE |
Model Number: | iDU500 series |
Payment & Shipping Terms:
Minimum Order Quantity: | 1piece |
---|---|
Price: | Negotiable |
Packaging Details: | Carton box |
Delivery Time: | 5-30 days based on order qty |
Payment Terms: | T/T |
Detail Information |
|||
Output Voltage: | 24VDC/48VDC | Peak Power: | 500W |
---|---|---|---|
Communication: | RS485 Protocol | Efficiency: | 90% |
Protection: | Output Short Circuit | Brand: | TBB |
Dimension: | 158*110*45MM | Charging: | 6 Steps |
Charging Current: | 3A | ||
High Light: | industrial dc power supply,12v ups power supply |
Product Description
Self - Cooling 24v / 48v Dc Ups Power Supply Idu Device For Industrial
Self - Cooling 24v / 48v Dc Ups Power Supply Idu Device For Industrial
iDU is a DC UPS integrating multiple functions into one unit, including a smart battery charger, battery monitor and the load management. The built-in professional adaptive charging algorithm with automatic temperature charging makes it suitable for composing a power backup system for various outdoor equipments, such as DAS, RF and FTU etc.
Features
- Power factor correction.
- Professional temperature compensated battery charging control.
- Working temperature: -40℃-70℃.
- Low power consumption.
- Self- cooling design.
- IP55 design.
- System data monitor via RS484 communication.
- Real-time power supply data.
- Real-time alarm data.
- Real-time battery data, including battery voltage and discharging current.
Schematic Diagram
- When AC grid is available, iDU offers 3 steps’ smart charging to the battery. At the same time, it offers the power supply to the load.
- When AC grid is not available, battery offers the energy to the loads. iDU alarms via dry contact.
- When battery discharged until the low voltage protection level, iDU cut off the output of battery and alarms via dry contact.
- When the battery in the floating state for a long time, in order to avoid plate passivation, the module will automatically periodically activation process, at the same time also provide remote manual activation interface and local activation key, convenient for the user to control the active state.
Structure
Port definitions
No. | Label | Description | No. | Label | Description |
1 | L | Live line of AC input | 12 | T1 | Temperature sensor port |
2 | PE | Earth line of AC input | 13 | T2 | |
3 | N | Neutral line of AC input | 14 | HK | Battery equilization interface |
4 | NC | Reserved | 15 | HG | |
5 | HOK | Dry contacts | 16 | VG | |
6 | VL | 17 | B- | Battery- | |
7 | VH | 18 | B+ | Battery + | |
8 | POK | 19 | VO- | DC outputs | |
9 | VC | 20 | VO- | ||
10 | A | RS485 port | 21 | VO+ | |
11 | B | 22 | VO+ |
Specification
Model | iDU500-12 | iDU500-24 | iDU500-48 | |
Output voltage (V) | 14.4 | 28.8 | 57.6 | |
Output current(A) | Nominal current | 8 | 3.5 | 2 |
Peak current(15S) | 20 | 20 | 10 | |
Nominal Input Voltage | 165-265VAC,50/60HZ | |||
Charging curve | 3 steps smart charging | |||
Temperature compensation | Automatic temperature compensation | |||
Absorption voltage(V) | 14.4 | 28.8 | 57.6 | |
Floating voltage(V) | 13.5 | 27 | 54 | |
Charging current (A) | 3 | 1.5 | 1 | |
Equilization | Automatic/Manual | |||
Efficiency | 90% | |||
Ripple noise | ≤500mVp-p | |||
Voltage precision | ≤2% | |||
Cooling | no fans | |||
Working temperature | -40℃~ +70℃: full load at 60℃ and derating 60% at 70℃ | |||
Communication | RS485 | |||
Dry contact | AC grid fault, Battery low voltage, unit fault and Battery equilization | |||
Battery low voltage protection(VDC) | 11 | 22 | 44 | |
Battery EQ voltage protection(VDC) | 11.5 | 23 | 46 | |
Protection | ||||
Output short circuit | Unit cut down the outputs,restart automatically when the issue disappears | |||
Battery connection reverse polarity | No output | |||
Charger over temperature | Derate the output | |||
Battery over temperature | Stop charging | |||
Certification | ||||
LVD | EN60335-1,EN60335-2-29 | |||
EMC | EN55014-1,EN55014-2,EN61000-3-2,EN61000-3-3 | |||
Structure | ||||
Outcase | Aluminum | |||
Dimension | 168x110x45 | 168x110x45 | 168x110x45 | |
168x110x45 | 1kgs | 1kgs | 1kgs | |
IP protection | IP55 | |||
Mounting | Wall mount | |||
Isulation safety | ||||
Isulation resistance | ≥50M | |||
Dimension | 2.5KV/1min/5mA |